Untitled Document
Argus Analyzers
AA350 Digital Battery Analyzer
Technology
| LPR Tests |
Yes |
| CrankCheck Test |
No - Not Available |
| Alternator Test |
Voltage Only |
Operating Parameters
| Battery Voltage |
6 or 12 Volts |
| Input Voltage |
9 - 16 VDC |
| Power Requirements |
None |
| Operating Temp |
14° F to 140° |
| Battery Size Range |
30 to 2000 CCA |
| Test Clamps |
Dual Contact Clamps |
| Test Time |
<1 Second |
| Safety Standards |
CE |
| Warranty |
2 Years |
Display and Interface
| Buttons |
Three |
| Display Type |
LCD w/Backlight |
| Display Info. |
Digital, Graphical & Icons |
| Optional Printer |
No - Not Available |
Basic Battery and System Diagnostics
| State of Charge (SoC) |
Graph and % |
| Bad Cell Detection |
Yes |
| Volt Meter Mode |
Yes |
| Reverse Protection |
Yes |
| Battery Pass/Fail |
Icon & Audible |
CrankCheck Starting System Diagnostics
| Starting System |
Graph and % |
| Measurement Mode |
Real Time Engine Load |
| Low Voltage Capture |
Yes |
| Crank Perf. Indicator |
Yes |
LPR Battery Life Diagnositics
| CCA Test |
Yes |
| Battery Norms |
SAE/EN/DIN/IEC |
| Battery Types |
WET/MF/VRLA/AGM |
| Present Capacity |
Yes |
| Remaining Battery Life |
Yes |
| Battery Life Warning |
No |
| Battery Resistance |
No |
| SoC Compensation |
Yes |
| Temp. Compensation |
Automatic |
Charging System Diagnostics
| Alternator Pass/Fail |
No |
| Alternator Voltage |
Yes |
| Diode Ripple Test |
No |
| Over/Under-Charging |
No |
Physical Specifications
| Dimensions |
6.73" x 3.11" x .98" |
| Weight |
260g |
| House |
ABS Plastic (IEC 68-2-32) |
| Protective Case |
None |
If you have any questions regarding the Argus AA350 Digital Battery Analyzer please feel free to email our Sales Department at sales@remybattery.com!